If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS70H38.doc version 1.1 11.09.01 VI TELEFILTER Measurement condition Ambient temperature: 23 C Input power level: 10 dBm Terminating impedances : for input: for output: 50 50 Filter Specification TFS 70H38 1/5 || 0 pF || 0 pF Remark: Reference level for the relative attenuation arel of the TFS 70H38 is the insertion loss. The insertion loss ae is defined as the insertion loss at the nominal frequency fn . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tc f is valid for both the reference frequency f c and the frequency response of the filter on the operating temperature range. Data Insertion loss (Reference level) Nominal frequency ae fn typ. value 23,5 dB tolerance/limit max. 25,0 dB 70,0 MHz Passband Passband variation 1 dB bandwidth 3 dB bandwidth 40 dB bandwidth PB p-p BW BW BW fn 5,7 0,6 MHz dB MHz MHz MHz 0,4 11,79 12,14 15,11 dB MHz MHz MHz min. min. max. 11,6 12,0 15,4 Relative attenuation arel fn 5,7 MHz .......fn + fn 5,7 MHz .......fn fn fn fn 5,8 MHz ....... fn 5,7 MHz 5,8 MHz 6,0 MHz 60 65 2,8 35 dB dB ns max. max. max. min. min. max. max. 0,6 1 3 40 55 4 60 dB dB dB dB dB ns C C 7,7 MHz ....... fn 10,0 MHz 10,0 MHz ....... fn 20,0 MHz Phase linearity in PB (p-p) Group delay variation in PB (p-p) Operating temperature Storage temperature range Temperature coefficient of frequency ( Tcf ) Frequency deviation of f c over temperature T: - 20..... + 70 - 25..... + 85 -75 ppm/K fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) Generated: Checked / approved: VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS70H38.doc version 1.1 11.09.01 VI TELEFILTER Filter Specification TFS 70H38 2/5 Construction, pin configuration and 50 (All dimensions in inch) 22,5 max. - matching network 13 max. 5,0 max. 5,6 max. 0,45 dia. 7,62 2,54 0,2 6x2,54 = 15,62 TFS 70H38 N37 12 7 Date-code: L M N ....... Year+week 1999 2000 2001 ....... Pin 14 Pin 1 Pin 8 Pin 7 Pin 2, 9 14 9 8 Input Input RF Return Output Output RF Return Package Ground 50 Ohm test circuit 14 8 IN TFS 70H38 OUT 1, 2, 7, 9 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS70H38.doc version 1.1 11.09.01 VI TELEFILTER Filter Specification TFS 70H38 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 1,5 mm or 20g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 14 Test N max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS70H38.doc version 1.1 11.09.01 VI TELEFILTER Filter Specification TFS 70H38 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS70H38.doc version 1.1 11.09.01 VI TELEFILTER Filter Specification TFS 70H38 5/5 History version 1.0 1.1 reason of changes generate specification - terminated impedances added - typical values added - new definition of pass band name Pfeiffer Pfeiffer date 15.08.2001 11.09.2001 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS70H38 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |